Home About Us Products Physician Contact Feedback Career
 
 
 
 
Coronary
 
Graft Master
Guide Wires
NC Mercury
RX Herculink Plus
Trek & Mini Trek
Voyager NC
Xience Prime
Xience V
 
 
Graft Master
 
The JOSTENT coronary stent graft
The patented sandwich technique contents 2 JOSTENT Flex stents And an ePTFE layer in between.
The JOCATH  GraftMaster delivery system is based on the JOCATH Maestro balloon dilatation catheter.
   
Redial strength and visibility
The unique Flex design allows the stent to exert m aximum redial strength, an dhas superior visibility due to it's unique sandwich design
   
Expandable PTFE graft marerial
The PTFE graft material has been specifically de veloped by Abbott Vascular for integrating inoto astent grafts system. The PTFE material is contructed to allow expension in one direction, whilst remaining rigid longitudinally.
   
lnflate step by step to minimize foreshortening
2 bar/AfM2/sec
High post dilatation pressur to assure good vessel wall appositioning
Min. 14 - 16 bar/ATM
IVUS strongly recommended to ensure complete expansion
 
Top
 
 
Guide wires
 
Core Diameter
Larger core diameter provides increased suppot for device delivery and vessel straightening and more material for superb torque
Smaller core diameter provide enhanced tracking and flexibility
   
Core Materials
Stainless steel - original Core material technology
Durasteel stronger than conventional stainless steel for outstanding durability
Elastinite an advanced material known for its flexibility and durability poroperties offering exceptional push and torque control
 
Top
 
 
NC Mercury
 
Optimal deployment
Maximized wall apposition due to non-compliant blloon behaviour
Minimal balloon overhang designed to limit vessel injury during high pressure dilatation
   
Efficient deliverabiilty
Stainless steel - original Core material technology
Durasteel stronger than conventional stainless steel for outstanding durability
Elastinite an advanced material known for its flexibility and durability poroperties offering exceptional push and torque control
 
Top
 
 
RX Herculink Plus
 
DU RX Herculink Plus - Profil
Compatibilite guide/introducteur de profil bas:
Guide de 6F ou introducteur de 5F de 4,0 a`6,0mm.
Guide de 6F ou introducteur de 6F de 6,5 a`70mm.
La Compatibilite .014" assure une plate forme a profil
bas de haute technoligie
Profil bas de l'endoproth'ese comprim'ee assurant un
frenchissement facile et une pose efficase
   
Performance
Le mandrin conique assure une exlcellente efficacité du
push et support
Ballon en XCELON pour s'adapter aux dimensions
La petite taille du crops améliore l'administration du produit de contaste
 
Top
 
 
Trek & Mini Trek
 
Unique hypotube and flexible distal shaft
  Excellent tacile feel and less force required to cross
challenging anatomy. Skive design provides smooth
transition between hypotube and distal shaft.
 
Transitionlestsip
  Excellent guide wire conformability through resistant lesions while minimizing vessel trauma.
 
Slim Seal** technology
  Provides flexible ultra low distal seal profiles for outstanding deliverability.
 
Flexiblet ungsten markers
  Proprietary radiopaque markers for smooth tracking through tortuous anatomy.
 
Top
 
 
Voyager NC
 
Smooth, Rounded Distal Tip
For outstanding stent strut deflection and deliverability
through resistant lesions.
 
Flexible Tungsten Markers
For smooth track and guide wire conformability.
 
Co-Extruded Balloon
Proprietary bi-layer technology offering flat compliance and excellent balloon flexibility for superb track.
 
Top
 
 
Xience Prime
 
Significant Reductions in Stent Thrombosis
 
 
XIENCE PRIME is built on XIENCE V DES technology.
   
*XIENCE V was studied in SPIRIT lV and COMPARE.
  Source: Dr. Gregg stone, SPIRIT lV 1-Year results Presentation, TCT 2009. Dr. Gregg stone, SPIRIT lll, 3-Year Results Presentation TCT 2009. Dr. David Cox, SPIRIT lll, 3 -year Results TCT 2009.
   
TAXUS Express was the control in SPIRIT lV and SPIRIT lll.
  1 P-values based on Fisher's exact test.
  2 categorical data, 365 ± 28 days.
 
Top
 
 
Xience V
 
Everolimus Eluting Coronary Stent System
 
 
Tests performed and data on file at Abbott Vascular.

This nominal in vitro device specifications do not take into account lesion resistance. These measurements indicate stent sizing should be confirmed angiographically. Do not exceed RBP or expend the stent beyond 3.5 mm (for 2.5, 3.0 mm size) and 4.50 mm (for 3.5, 4.0 mm size).

 
Top